Flupyradifurone [987]

Content Handbook P

 

Outline of method

Flupyradifurone content is determined (g/kg) by reversed phase high performance liquid chromatography using UV detection at 280 nm and
external standard calibration.

 

Scope

The method is usable for TC, AL, EC, EW, FS, SL and WG-formulations.

Fenazaquin [693]

Content Handbook P

 

Outline of method

Fenazaquin is determined by reversed phase high performance liquid chromatography using UV detection at 260 nm using an external standard technique.

Scope

The method is usable for TC and SC-formulations

MT 1 - Freezing point

 

Content Handbook F

 

Outline of method

The sample is heated to a temperature above its melting point and then allowed to cool in a temperature controlled jacket. The freezing point is taken as that temperature of the material which remains constant to within 0.5 °C for 4 min.