MT 139 - Pour point of mineral oil


Content Handbook F

 

Outline of method

After preliminary heating the sample is cooled at a specified rate and examined at intervals of 3°C for flow characteristics. The lowest temperature at which movement of the oil is observed is recorded as the pour point.
 

Scope

The test for pour point is intended for use on any petroleum oil.