28-Homobrassinolide [1006]

 

Content Handbook Q


Outline of method

28-Homobrassinolide is first derivatized with phenylboronic acid and the product is separated and determined by HPLC on ODS-C18 film stainless column using UV detection at 220 nm and external standard calibration.


Scope

The method is usable for TC, SL and EC formulations.