Pyridaben
Beta-cyfluthrin
Content Handbook J
Outline of method
The sample is dissolved in acetonitrile containing laurophenone as internal standard. Pyridaben is determined by reversed phase high performance liquid chromatography on a C8 phase using acetonitrile - water (75 + 25) as mobile phase.
Scope
The method is usable for TC, WP and SC-formulations.
The method is usable for TC, SC and EC-formulations.